Pole Specifications You Need Without the Chase

Composite Pole Data Built for Decision Makers

Composite Pole Classes. Quick Specs, Clear Options

EnduraPOLE™ AT A GLANCE



EnduraPOLE™ 30′ 35′ 40′ 45′ 50′ 55′ 60′
Outside Diameter 12.0″ 12.0″ 12.0″ 12.0″ 12.0″ 12.0″ 12.0″
Inside Diameter 11″ 11″ 11″ 11″ 11″ 11″ 11″
Weight (lbs.)* 473 552 630 709 788 867 946
Pole Class by Strength – NESC Grade B H6 H5 H4 H3 H2 H1 H1
Pole Class by Strength – NESC Grade C H4 H3 H2 H1 Class 1 Class 1 Class 2
Pole Class by Deflection** Class 1 Class 1 Class 1 Class 2 Class 3 Class 3 Class 3

EnduraPOLE™ 9.14 m 10.67 m 12.19 m 13.72 m 15.24 m 16.76 m 18.29 m
Outside Diameter 304.8 mm 304.8 mm 304.8 mm 304.8 mm 304.8 mm 304.8 mm 304.8 mm
Inside Diameter 279.4 mm 279.4 mm 279.4 mm 279.4 mm 279.4 mm 279.4 mm 279.4 mm
Weight (kg.)* 214 250 286 322 357 393 429
Pole Class by Strength – NESC Grade B H6 H5 H4 H3 H2 H1 H1
Pole Class by Strength – NESC Grade C H4 H3 H2 H1 Class 1 Class 1 Class 2
Pole Class by Deflection** Class 1 Class 1 Class 1 Class 2 Class 3 Class 3 Class 3

* Weight includes installed top cap and base plate, exclusive of hardware and steps.

** Class by Deflection – When the EnduraPOLE is subjected to ANSi class loads the deflection will be less than 110% of a Western Red Cedar Pole of similar length and class.

30′ Pole

Metric Length: 9.14 m

Outside Diameter: 12″ (304.8 mm)

Inside Diameter: 11″ (279.4 mm)

Max Weight (lbs.)*: 473

Max Weight (kg)*: 214

Class by Strength:
Grade B: H6
Grade C: H4

Class by Deflection**: Class 1

35′ Pole

Metric Length: 10.67 m

Outside Diameter: 12″ (304.8 mm)

Inside Diameter: 11″ (279.4 mm)

Max Weight (lbs.)*: 552

Max Weight (kg)*: 250

Class by Strength:
Grade B:
H5
Grade C:
H3

Class by Deflection**: Class 1

40′ Pole

Metric Length: 12.19 m

Outside Diameter: 12″ (304.8 mm)

Inside Diameter: 11″ (279.4 mm)

Max Weight (lbs.)*: 630

Max Weight (kg)*: 286

Class by Strength:
Grade B: H4
Grade C: H2

Class by Deflection**: Class 1

45′ Pole

Metric Length: 13.72 m

Outside Diameter: 12″ (304.8 mm)

Inside Diameter: 11″ (279.4 mm)

Max Weight (lbs.)*: 709

Max Weight (kg)*: 322

Class by Strength:
Grade B: H3
Grade C: H1

Class by Deflection**: Class 2

50′ Pole

Metric Length: 15.24 m

Outside Diameter: 12″ (304.8 mm)

Inside Diameter: 11″ (279.4 mm)

Max Weight (lbs.)*: 788

Max Weight (kg)*: 357

Class by Strength:
Grade B: H2
Grade C: Class 1

Class by Deflection**: Class 3

55′ Pole

Metric Length: 16.77 m

Outside Diameter: 12″ (304.8 mm)

Inside Diameter: 11″ (279.4 mm)

Max Weight (lbs.)*: 867

Max Weight (kg)*: 393

Class by Strength:
Grade B: H1
Grade C: Class 1

Class by Deflection**: Class 3

60′ Pole

Metric Length: 18.29 m

Outside Diameter: 12″ (304.8 mm)

Inside Diameter: 11″ (279.4 mm)

Max Weight (lbs.)*: 946

Max Weight (kg)*: 429

Class by Strength:
Grade B: H1
Grade C: Class 2

Class by Deflection**: Class 3

* Weight includes installed top cap and base plate, exclusive of hardware and steps.

** Class by Deflection – When the EnduraPOLE is subjected to ANSI class loads the deflection will be less than 110% of a Western Red Cedar Pole of similar length and class.

EnduraPOLE™ Properties

Mechanical Properties Imperial Metric
Flexural Strength per ASTM D1036 - 5% LEL 44,000 psi 303.37 Mpa
Compression Strength per ASTM D1036 - 5% LEL 44,000 psi 303.37 Mpa
Axial Compression Strength - 5% LEL 44,000 psi 303.37 Mpa
Modulus of Elasticity - Average 4,312,000 psi 29,730.19 Mpa
Bending Stiffness (EI) per ASTM D1036 1.289E+9 lbs-in² 3.77E+11 kg-mm²
Ultimate Moment Capacity per ASTM D1036 183,000 lb-ft 248.11 kN-m
Max Bolt Torque 50 lb-ft 67.8 N-m
Ultimate Bolt Bearing Strength Lengthwise (lb) - 5/8" bolt (psi) 10,300 lb 45,817 N
Ultimate Bolt Pull Through Strength (lb) (0.25"x2.5"x2.5" square curved washer) (5/8" bolt) 7,700 lb 34,251 N
Guy Load Test (5/8" bolts) 33,000 lb 146,791 N
Physical Properties Imperial Metric
Outer Diameter 12 in 304.8 mm
Inner Diameter 11 in 279.4 mm
Wall Thickness 0.5 in 12.70 mm
Cross Sectional Area 18.064 in² 11654 mm²
Moment of Inertia 299.19 in⁴ 1.24E+8 mm⁴
Section Modulus 49.86 in³ 818,059 mm³
Radius of Gyration 4.0697 in 103.37 mm
Density 0.0709 lb/in³ 1.9625 g/cm²
Weight 15.375 lb/ft 22.88 kg/m
Surface Area 3.14159 ft²/ft 0.2827 m²/m
Electrical Properties Imperial Metric
ASTM F711 Pass Pass
Miscellaneous Tests Imperial Metric
Salt Fog - ASTM B117 Pass Pass
Accelerated Age Test - ASTM G154 Pass Pass
Mechanical Properties

Flexural Strength per ASTM D1036 – 5% LEL
Imperial: 44,000 psi
Metric: 303.37 Mpa

Compression Strength per ASTM D1036 – 5% LEL
Imperial: 44,000 psi
Metric: 303.37 Mpa

Axial Compression Strength – 5% LEL
Imperial: 44,000 psi
Metric: 303.37 Mpa

Modulus of Elasticity – Average
Imperial: 4,312,000 psi
Metric: 29,730.19 Mpa

Bending Stiffness (EI) per ASTM D1036
Imperial: 1.289E+9 lbs-in²
Metric: 3.77E+11 kg-mm²

Ultimate Moment Capacity per ASTM D1036
Imperial: 183,000 lb-ft
Metric: 248.11 kN-m

Max Bolt Torque
Imperial: 50 lb-ft
Metric: 67.8 N-m

Ultimate Bolt Bearing Strength Lengthwise (lb) – 5/8″ bolt (psi)
Imperial: 10,300 lb
Metric: 45,817 N

Ultimate Bolt Pull Through Strength (lb) (0.25″x2.5″x2.5″ square curved washer) (5/8″ bolt)
Imperial: 7,700 lb
Metric: 34,251 N

Guy Load Test (5/8″ bolts)
Imperial: 33,000 lb
Metric: 146,791 N

Physical Properties

Outer Diameter
Imperial: 12 in
Metric: 304.8 mm

Inner Diameter
Imperial: 11 in
Metric: 279.4 mm

Wall Thickness
Imperial: 0.5 in
Metric: 12.70 mm

Cross Sectional Area
Imperial: 18.064 in²
Metric: 11654 mm²

Moment of Inertia
Imperial: 299.19 in⁴
Metric: 1.24E+8 mm⁴

Section Modulus
Imperial: 49.86 in³
Metric: 818,059 mm³

Radius of Gyration
Imperial: 4.0697 in
Metric: 103.37 mm

Density
Imperial: 0.0709 lb/in³
Metric: 1.9625 g/cm²

Weight
Imperial: 15.375 lb/ft
Metric: 22.88 kg/m

Surface Area
Imperial: 3.14159 ft²/ft
Metric: 0.2827 m²/m

Electrical Properties

ASTM F711
Imperial: Pass
Metric: Pass

Miscellaneous Tests

Salt Fog – ASTM B117
Imperial: Pass
Metric: Pass

Accelerated Age Test – ASTM G154
Imperial: Pass
Metric: Pass

Why Do Our Specs Matter?Because What You Build Depends On What You Know

Engineered performance begins with accessible, reliable data. Every spec and file we share reflects our commitment to engineering clarity and grid-ready resilience.

Validated Load and Deflection Data from Engineering Testing

Meets Your Utility's Strength and Deflection Requirements

ANSI and ASTM Compliance for Confidence in Every Pole

Inherently Non-conductive and Non-toxic

Still Have Questions?

Our engineers are ready to help you validate, customize, or apply what you download.